AA-D-600D
4.4.8.2.2 Surreptitious, covert and forced entry test timing. The time clock shall be started when the test equipment is picked up to approach the sample and shall not be stopped during the test except as specified above. Any change or repair of tools taken from the carrying case during a test shall only be done while the clock is running. The tests must be conducted in a manner that is repeatable. Any surreptitious, covert, or forced entry through the vault door under the above conditions, within the time specified for the door's class, shall provide reason to consider the door as having failed to meet the requirement.
4.4.8.3 Ballistic resistance test. The vault door shall be tested in accordance with level 2 small arms ballistic protection testing in accordance with the procedures specified in paragraph 3.2 of state department standard SD-STD-01.01, Revision G (Amended) dated November 30, 1992 amended April 30, 1993. Any failure of the tested item to comply with the criteria of paragraph 3.4.1
Ballistic Rejection Criteria of SD-STD-01.01 shall be cause for rejection.
4.4.8.4 Finish test. The two panels, prepared as specified in 3.13.2 shall, at room temperature, be bent around a 6.4 mm rod to an angle of 180 degrees. The panels shall then be examined for compliance with 3.13.2.
4.4.8.5 Escape device operational test. The escape device shall be subjected to 10,000 cycles of operation without addition of lubricants and without replacements of any component. One cycle shall consist of using the escape device to throw the bolts and open the vault door, and then close and lock the vault door. Any failure of the escape device during test shall be cause for rejection.
4.4.9 Inspection. A visual inspection shall be made of the product to determine compliance with the requirements specified in Section 3.
5. PREPARATION FOR DELIVERY
5.1 Packing. Packing shall be level A, B or C, as specified (see 6.2).
5.1.1 Level A. Each complete door shall be packed in a crate or in a box . When packed in a crate, the contents shall be waterproof shielded with a shroud. When packed in a box, the contents shall be shrouded and the box shall be modified with addition of reinforcing members and skids.
The contents of the crate or box shall be blocked, braced and cushioned to prevent movement during multiple shipments.
5.1.2 Level B. Each complete door shall be packed in a crate or in a box. Unless otherwise specified (see 6.2), shrouding of the contents shall not be required. The contents of the crate or box shall be blocked, braced, and cushioned to prevent movement during shipment.
5.1.3 Level C. Each complete door shall be packed to assure carrier acceptance and safe
delivery to destination in containers complying with the rules and regulations applicable to the mode of transportation.
14
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business